  1. General information
  2. Installation
  3. Humidity Adjustment
  4. Turning off and on
  5. Filling the tank
  6. Changing the batteries
  7. Technical specifications

Smoking.fr provides you with the user manual in French for the CigarSpa, whose reputation is well established. Find the CigarSpa humidifier for sale in your online store specializing in cigar accessories.

Discover on Smoking.fr
Cigarspa humidifier
Hygrometer
Cigar range


écran cigarspa

General information

CigarSpa optimizes the storage conditions in your humidor and ensures that your cigars develop their best flavors when you smoke them. CigarSpa achieves this by measuring and regulating the humidity in the ambient air of your cigars.

A large area for water evaporation is placed on the top of the device. It consists of a breathable membrane. This material retains water but allows water vapor to pass through. When the humidity level is too low, a small pump sends water under this membrane.

The water evaporates and increases the humidity level in your humidor. CigarSpa is equipped with a microcontroller that reliably regulates the relative humidity.

CigarSpa operates with demineralized water (without colorants) and with batteries.

Under normal usage conditions, the batteries last about one year. Water consumption is influenced by your humidor and your cigars. Normally, a full tank should be sufficient for 4 months of use.

In addition to humidity regulation, Cigarspa provides you with a lot of information on the preservation of your cigars.

Four measurements are visible on the CigarSpa screen.

mesures cigarspa

Cigarspa checks if the water tank is empty and the status of the batteries. If the 'water low' indicator is visible, you need to fill the tank. If the 'battery low' indicator is visible, you need to change the batteries.
batterie faible cigarspa
Once the maintenance operations have been carried out, press the blue button once to reactivate the system.
standby cigarspa
In the middle of the screen, the "stand-by" symbol is visible. This symbol only disappears when the CigarSpa recalculates the data (every 30 minutes) or when you press the blue button once. After about 5 seconds, the "stand-by" light reappears.

Installation

Cigarspa comes with batteries. You will find it in the off mode. Cigarspa only works in a horizontal position with the screen on top. Before turning on the device, you must fill the tank (use the funnel).

Then press the blue button once. Cigarspa starts and begins regulating the humidity. After a few days, CigarSpa will condition your humidor and your cigars to the humidity level you have selected.

Use only demineralized water without coloring.

Humidity Adjustment

The CigarSpa user can choose their preferred humidity level between 65 and 75%. The humidity level selected at delivery is 71%.

According to our experience, cigars develop their best flavors when stored at 71%. To adjust your humidity level Favorite, press the blue button once and then press it with small quick taps on the same button. You will see the numbers scroll from 65 to 75 and then back to 65 and so on. Stop pressing when you have reached the humidity level you desire for your cigars.

As soon as you stop pressing the blue button and the indicator at the top right shows the chosen humidity level, after 5 seconds, the Cigarspa will return to normal mode and begin humidifying your cigars.

Turning off and on

To turn off the Cigarspa, press the blue button for 10 seconds. To turn it on, press once.

Filling the tank

Open the cap and fill with distilled water using a funnel, then replace the cap.

Changing the batteries

When the "battery low" indicator is visible, you need to change the batteries. To avoid any problems, empty the water tank before performing the operation.

Using a Phillips screwdriver, unscrew the screw, remove the used batteries and replace them as indicatedon the diagram located in the battery compartment. Replace the cover, screw it back, and refill the tank.

Technical specifications